Thermal-vacuum tests of BepiColombo MPO and MTM solar array coupons
Home
/
Projects
/
Space
/
Thermal-vacuum tests of BepiColombo MPO and MTM solar array coupons
TV Test
Solar Panel Specimen
Thermal-vacuum qualification testing with electrical measurements of several coupons of the BepiColombo solar array
Outgassing measurement with molecular witness plates at the chambers cold trap
Installation and test performance under cleanroom conditions
Temperture extremes: -170°C and +220°C
Vacuum: 1e-6mbar
Project details
Core competencies:
Space
Customers:
AIRBUS Defence & Space
previous item