Structural Integrity Assessment of Long Focus - Spectro Telescope (LF-ST) for ITER

 Home / Projects / Fusion / Structural Integrity Assessment of Long Focus - Spectro Telescope (LF-ST) for ITER
LF-ST (CAD)
LF-ST (CAD)

FE model of Main Optic
FE model of Main Optic

Sample stress linearization (acc. to RCC-MR)
Sample stress linearization (acc. to RCC-MR)

  • Structural analysis of the LF-ST of the H-alpha instrument for ITER
  • Analyses encompassing dead weight, seismic loads, thermal loads, and electromagnetic loads
  • Multidisciplinary analyses including computation of eddy currents and resulting electro-magnetic forces
  • Structural assessment according to RCC-MR / SDC-IC standards (stress categorization and linearization)

Project details

Core competencies: Fusion Research
Program: ITER
Customers: KTO

KRP Mechatec GmbH is an engineering services provider specialized in structural tests and analyses in the field of space, aviation, experimental research and other high-tech industries, certified according to DIN EN ISO 9001:2015.

 